What is LC DCP plate?

The limited contact dynamic compression plate (LC-DCP)

What is recon plate?

Reconstruction plates have deep notches on the edge of the plate. These notches are situated between the holes and allow contouring of the plate in all planes. Three plate sizes are available for use with 2.7, 3.5, and 4.5 cortex screws. The holes are oval to allow dynamic compression.

How does dynamic compression plate work?

Dynamic compression principle These holes are shaped like an inclined and transverse cylinder. The screw head slides down the inclined cylinder as it is tightened, the head forcing the plate to move along the bone, thereby compressing the fracture.

What is Lcdcp?

Definition. LCDCP. Limited Contact Dynamic Compression Plate (orthopedics; also seen as LC-DCP)

What is DCP in surgery?

A dynamic compression plate (DCP) is a metallic plate used in orthopedics for internal fixation of bone, typically after fractures. As the name implies, it is designed to exert dynamic pressure between the bone fragments to be transfixed.

What is a DHS surgery?

Dynamic hip screw (DHS) or Sliding Screw Fixation is a type of orthopaedic implant designed for fixation of certain types of hip fractures which allows controlled dynamic sliding of the femoral head component along the construct.

What is a cortical screw?

Orthopedics A type of orthopedic hardware used to provide fixation by itself or in conjunction with other devices; CSs have fine threads along the shaft and are designed to anchor in cortical bone.

What are the principles of plating?

5 basic elements of plating and principles of food presentation

  • Create a framework. Start with drawings and sketches to visualise the plate.
  • Keep it simple. Select one ingredient to focus on and use space to simplify the presentation.
  • Balance the dish.
  • Get the right portion size.
  • Highlight the key ingredient.

What is a good dynamic compression ratio?

As a general rule, the best available pump gas will work with an 8.0:1 dynamic compression ratio. To get 8.0:1 with the preceding rod, stroke, and cam intake closing event, you would need about a 13.2:1 static ratio.” Erb’s 8.0:1 dynamic guideline is for classic, old-school, all-iron engines.

What is an IM nailing?

An intramedullary nail is a metal rod that is inserted into the medullary cavity of a bone and across the fracture in order to provide a solid support for the fractured bone. Intramedullary nailing is currently considered the “gold standard” for treatment of femoral shaft fractures (Rudloff 2009).

What is K wire in surgery?

A Kirschner wire (also called a K-wire) is a thin metallic wire or pin that can be used to stabilize bone fragments. These wires can be drilled through the bone to hold the fragments in place. They can be placed percutaneously (through the skin) or can be buried beneath the skin.

What is a one third tubular plate?

Introduction. An inter-fragmentary lag screw protected by a lateral one-third tubular plate is the most commonly used fixation method for treating displaced lateral malleolar fractures. Difficulty achieving adequate screw thread purchase in the cancellous bone of the distal fragment can lead to the screws backing out.

What does LC-DCP plate 3.5 stand for?

LC-DCP Plate 3.5. LC-DCP Plate 3.5. These plates are indicated for fixation of fractures and nonunions of the Clavicle, Scapula, Olecranon, Humerus, Radius, Ulna, Pelvis, Distal tibia, and Fibula. The oval shaped hole is designed to create dynamic pressure between the fractured bone fragments.

Which is the neutral position on LC-DCP 3.5?

• neutral (green) and compression (yellow) position • for LC-DCP 3.5 The new plate hole is symmetrically shaped. It now pos- sesses one compression point and one neutral point on both sides. The two drill guides bear an arrow enabling correct positioning of the screw. 1 Neutral position

What kind of Screws do I need for a 3.5 DCP plate?

All holes of the plate allow 3.5 mm cortical and 4.0 mm cancellous screws. For Ulna & Radius. Fixation with 3.5mm & 4mm screws.

How is the LC-DCP used in bone compression?

A double fracture, spanned by the LC-DCP and lag screws through the plate. The ability to incline screws at up to 40° to the perpen- dicular permits an even wider range of applications. PLATE HOLE GEOMETRY UNIFORM IMPLANT STIFFNESS New plate design renders the LC-DCP uniformly stiff.